Industrial Switches
PSU : EDR-120-48
-
Overview
Power Supply Industrial Switches Enterprise 120W Industrial DIN Rail Power Supply – 48VDC/2.5A, Universal AC input, Metal Case (Slim), -20°C ~ 60°C
EDR-120 is one economical slim 75W DIN Rail Industrial power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails.
EDR-120 is designed with a metal housing that enhances the unit’s power dissipation. With working efficiency up to 88.5%, the entire series can operate at the ambient temperature between -20°C and 60°C under air convection. It is equipped with a constant current mode for overload protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV EN60950-1, etc.) make EDR-120 a very competitive power supply solution for industrial applications
Features
Universal AC input / Full range
Power Output: 48VDC / 2.5A / 120W
Efficiency: 88.5%
Metal case – Slim design
Protections: Short circuit / Overload / Over voltage / Over temperature
DC output voltage adjustable
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Operating temperature: -20℃ ~ 60℃
Safety standards: UL508, TUV EN60950-1 approved
Dimension: 40×125.2×113.5mm (WxHxD)
Applications
Industrial Control System
Semiconductor Fabrication System
Factory Automation
Smart City Deployment
Electro-Mechanical Apparatus
Specifications
BASIC | |
MODEL | EDR-120-48 |
BRAND | MEANWELL |
WARRANTY | 2 Year |
OUTPUT | |
DC VOLTAGE | 48V |
RATED CURRENT | 2.5A |
CURRENT RANGE | 0 ~ 2.5A |
RATED POWER | 120W |
OUTPUT RIPPLE & NOISE (max.) | 150mVp-p |
VOLTAGE ADJ. RANGE | 48 ~ 55V |
VOLTAGE TOLERANCE | ±1.0% |
LINE REGULATION | ±0.5% |
LOAD REGULATION | ±1.0% |
SETUP, RISE TIME | 1200ms, 60ms/230VAC, 2000ms, 60ms/115VAC at full load |
HOLD UP TIME (Typ.) | 16ms/230VAC 10ms/115VAC at full load |
INPUT | |
FREQUENCY RANGE | 47 ~ 63Hz |
VOLTAGE RANGE | 90 ~ 264VAC, 127 ~ 370VDC, [DC input operation possible by connecting AC/L(+), AC/N(-)] |
EFFICIENCY (Typ.) | 88.5% |
AC CURRENT (Typ.) | 2.25A/115VAC 1.3A/230VAC |
INRUSH CURRENT (Typ.) | 20A/115VAC 35A/230VAC |
LEAKAGE CURRENT | <1mA / 240VAC |
PROTECTION | |
OVERLOAD | 105 ~ 130% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed |
OVER VOLTAGE | 56 ~ 65V |
PROTECTION TYPE | Shut down o/p voltage, re-power on to recover |
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover |
ENVIRONMENT | |
WORKING TEMP. | -20 ~ +60℃ (Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) |
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
SAFETY & EMC (Note 4) | |
SAFETY STANDARDS | UL508, TUV EN60950-1 approved;(meet EN60204-1) |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH |
EMC EMISSION | Compliance to EN55032 (CISPR32) Class A, EN61000-3-2,-3 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A |
OTHERS | |
MTBF | 506.6K hrs min. MIL-HDBK-217F (25℃) |
DIMENSION | 32*125.2*102mm (W*H*D) |
PACKING | 0.51Kg; 28pcs/15.3Kg/1.22CUFT |
/p>